Skip to main content
Proven Results

Case Studies

Real platforms. Real data. Real clinical impact.

Chronus Health whole-blood CBC reader device
01 · Flagship Engagement

Chronus Health

Whole-Blood Electrical Detection Platform

Co-founded and built a CLIA-waiver candidate POC device for CBC, CMP, and electrolytes from undiluted whole blood — no sample prep, no optical detection. From bench feasibility through IRB-approved clinical studies and FDA pre-submission.

CBC · CMP · ElectrolytesElectrochemical DetectionPoint-of-CareFDA Pre-Submission
$28M+
Raised
r=0.96
CBC correlation
r²=0.99
Electrolytes
Aptamer-based electrochemical biosensor — surface immobilization and amperometric current response
02 · Assay Development

Confidential — IVD Startup

Multiplexed Aptamer Biosensor Development

End-to-end development of a multiplexed electrochemical biosensor for a serum protein panel. Scope included aptamer selection and screening, surface chemistry optimization, and prototype validation against reference methods.

Aptamer DevelopmentSurface ChemistryElectrochemical SensingPrototype Validation
NDA
Client confidential
6
Analyte targets
r>0.90
Correlation achieved
Details under NDA — available on request
96-well ELISA plate for hormone detection assay
03 · Feasibility Study

Confidential — IVD Startup

Hormone Detection via Competitive Assay Feasibility

Feasibility study for electrochemical detection of a small-molecule hormone using a competitive assay format. Scope included assay design, surface chemistry optimization, and proof-of-concept validation against reference methods.

Competitive AssayHormone DetectionElectrochemical SensingFeasibility
NDA
Client confidential
POC
Proof-of-concept achieved
<20min
Time to result
Details under NDA — available on request
Na+, K+ and Ca2+ ion symbols for electrolyte detection
04 · Sensor Development

Confidential — Diagnostics Company

Sodium, Potassium & Calcium Ion-Selective Electrode Detection

Development of ion-selective electrodes (ISEs) for simultaneous electrochemical detection of sodium, potassium, and calcium in whole blood. Scope included membrane formulation, electrode fabrication, and clinical correlation against a reference analyzer.

Ion-Selective ElectrodesElectrolyte DetectionWhole BloodElectrochemical Sensing
NDA
Client confidential
3
Electrolytes detected
r²>0.97
Clinical correlation
Details under NDA — available on request
Amperometric glucose sensor strip inserted into potentiostat reader
05 · Sensor Development

Confidential — MedTech Company

Glucose Detection via Amperometric Electrochemical Sensing

Development of an amperometric glucose biosensor for whole-blood detection. Scope included enzyme immobilization chemistry, mediator selection, electrode optimization, and performance validation across clinically relevant glucose ranges.

Amperometric DetectionGlucose BiosensorEnzyme ImmobilizationPoint-of-Care
NDA
Client confidential
r²>0.98
Clinical correlation
<1min
Time to result
Details under NDA — available on request

Building Something in Diagnostics?